Official source, edition and navigation
Use the IWBI WELL v2 standard and edition selector: choose Access Now → WELL v2, Q2 2025 → Mind → M02 Nature and Place → Requirements / Verification. For optional nature access, choose Mind → M09 Enhanced Access to Nature → Part 1, Provide Nature Access Indoors. Direct feature addresses can be unreliable; the standard entry and this navigation path identify the provision without relying on a deep link.
The LEED/WELL comparison remains the detailed reference for editions, thresholds and verification methods. The office workflow below is a practical drawing and narrative suggestion, not an additional IWBI submission requirement.
M02: document both required parts
Part 1 — Provide Connection to Nature
The reviewed requirement integrates both natural materials, patterns, shapes, images or sounds and at least one of plants, water or nature views throughout the applicable space, including common circulation routes, shared seating areas and rooms (such as conference rooms and common spaces), and workstations as applicable. A single planted corner does not establish that coverage.
Part 2 — Provide Connection to Place
The project must integrate design elements addressing all four topics: celebration of culture (occupants, workplace or surrounding community), celebration of place (such as local architecture, materials, flora or artists), integration of art, and human delight. A plant label or generic nature image alone does not explain the project's identity.
Official verification: both parts list Professional Narrative. Plans, schedules and images may help the team explain its strategy; this guide does not turn them into a prescribed M02 drawing package.
Illustrative office example: a planter beside a lounge seat
An office team proposes a freestanding planter next to a lounge seat in a shared seating area. This is an illustrative design proposal, not a documented project, a points calculation or a certification result.
1. Record what the seating plan can establish
Tag the planter and seat on the proposed plan. Show their locations, relevant obstructions and the intended view of the plant from the seat. The drawing can establish the proposed spatial relationship and support a sightline or distance investigation. It cannot establish installed conditions, whole-project nature coverage or connection to place by itself.
2. Expand the record beyond that seat for M02
- Nature narrative: identify the natural materials, patterns, shapes, images or sounds and the plants, water or nature views integrated through circulation routes, shared seating, rooms and workstations as applicable. Review missing areas, rather than assuming the lounge planter covers the office.
- Place narrative: explain the actual design decisions addressing culture, place, art and human delight. Record the chosen elements and their relationship to this project's occupants and setting; do not invent a local artist, material provenance or community story.
- Practical coordination: cross-reference the planter schedule for size, fit, containment and service responsibilities. An annotated plan, finish references and image captions can help organize the narratives, but are practical suggestions, not substitutes for official verification.
Compare the WELL v2 M02 row: both parts and Professional Narrative verification.
3. Add seat-level evidence only if pursuing M09 indoor access
Inventory all applicable workstations, conference room seats, classroom seats and seating within common spaces across the project—not just the lounge seat. Identify which have direct sight to indoor plants, water features and/or nature views, or are within 33 ft (10 m). Use the full applicable seat/workstation count as the denominator and document the qualifying count against the reviewed 75% threshold. Do not use planted square footage or count an overlapping seat twice.
Official verification: M09 Part 1 lists Technical Document (Audited). Practical drawing suggestions: a numbered seating plan, qualifying-seat register, annotated sightlines or dimensions, and obstruction notes can help the team assemble that evidence. Confirm the edition's submission instructions with the project team; this suggested package does not itself demonstrate acceptance or award points.
Compare the WELL v2 M09 indoor-access row: threshold, denominator and verification. M09 also has an outdoor-access part; the indoor example does not document that separate pathway.
Still to resolve: registration scope and edition, applicable addenda, the complete nature and place strategy, final seating and workstation inventory, qualifying access evidence and the required submissions. Neither the planter proposal nor this guide demonstrates achievement of a WELL feature or certification.
Keep other features independent
Planting does not establish Air, Light, Sound, Community or restorative-space compliance. Check each exact feature and evidence independently; do not add generic points, acoustic coefficients, maintenance thresholds or survey promises to a plant specification.
Research is not compliance evidence by itself
Nieuwenhuis et al. (2014): Across three field experiments in commercial offices in the Netherlands and the UK, researchers studied how adding plants affected employees’ perceptions of their workspace and their performance. One experiment found improved perceived productivity; another found improved performance on an objectively measured task. The findings apply to the workplaces and tasks studied. Source.
Allen et al. (2016; online 2015): In a controlled office study, researchers varied ventilation, carbon dioxide levels, and volatile organic compound exposure and measured participants’ cognitive test scores. The study provides evidence about indoor air quality. It did not test an interior planting intervention. Source.
Neither study establishes a guaranteed financial return or demonstrates achievement of a WELL feature.